Technical data
Performance standards
- Thermal conductivity = 0.035 W/mK
- Density: 30 kgm-3
- Water absorption (@100% RH) = 24% w/w
- Mould resistance: CUAP 2002-01-25
- Moth/ beetle proofing: ISO 3998
- Ignition point: >500 degrees C
- Spread of fire: BS 5803-4
- Vapour resistivity: 9 MN s/g
- Specific heat capacity: 1800 Jkg-1K-1
- Manufactured to ISO 9001 & 14001
Environmental data
Performance measure
Recycled content: 37.5%
Thermal resistances provided by various thicknesses of Thermafleece TF35
| Thickness (+/- 5mm) (mm) | Thermal resistance (Km2/W) |
| 50 |
1.43 |
| 70 | 2.00 |
| 100 |
2.86 |
| 140 |
4.00 |
| 190 |
5.43 |
| 240 |
6.86 |